Building energy and IAQ improvement by coupled model

Téléchargements

Téléchargements par mois depuis la dernière année

Plus de statistiques...

Heibati, Seyedmohammadreza, Maref, Wahid et Saber, Hamed. 2019. « Building energy and IAQ improvement by coupled model ». In 10th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings (IAQVEC) (Bari, Italy, Sept. 05-07, 2019) Coll. « IOP Conference Series: Materials Science and Engineering », vol. 609. Institute of Physics Publishing.
Compte des citations dans Scopus : 2.

[thumbnail of Maref W 2019 19840.pdf]
Prévisualisation
PDF
Maref W 2019 19840.pdf - Version publiée
Licence d'utilisation : Creative Commons CC BY.

Télécharger (683kB) | Prévisualisation

Résumé

The building performances are related to Energy Efficiency and Indoor Air Quality (IAQ). Modeling is one of the best accurate tools for measuring the building performance. Nowadays, Energy Efficiency and IAQ are modeled individually for buildings. Improvement strategies in both areas are analyzed separately. The fundamental problem in Energy and IAQ modeling is related to interaction to each other. This problem makes the modeling results unrealistic to the building performance solutions. To avoid this problem, in this current research, Energy and IAQ models are coupled simultaneously as a new co-simulation method. EnergyPlus and CONTAM are used as Energy and IAQ models, respectively. With the co-simulation method, these two models are coupled together. The method is based on the exchange of control variables between both models dynamically and simultaneously. As a result, the exchanges of temperature and air flow variables are corrected. The verification of the new model is based on the comparison of the simulation and analytical results of temperature and air flow variables. In the next step, this new coupling-co-simulation method for a townhouse building is done in two cases: a leaky and a tight building envelopes. Both cases are compared in two types of ventilation systems: infiltration only, and exhaust only. At this point, the simulated air change rates, gas energy use, and particles concentrations are compared for each case. Finally, the necessity of the accuracy of this new method is concluded.

Type de document: Compte rendu de conférence
ISBN: 17578981 (ISSN)
Éditeurs:
Éditeurs
ORCID
Berardi, U.
NON SPÉCIFIÉ
Allard, F.
NON SPÉCIFIÉ
Professeur:
Professeur
Maref, Wahid
Affiliation: Génie de la construction
Date de dépôt: 20 nov. 2019 21:38
Dernière modification: 03 déc. 2019 16:37
URI: https://espace2.etsmtl.ca/id/eprint/19840

Actions (Authentification requise)

Dernière vérification avant le dépôt Dernière vérification avant le dépôt