FRANÇAIS
A showcase of ÉTS researchers’ publications and other contributions
SEARCH

Heart motion abnormality detection via an information measure and bayesian filtering

Downloads

Downloads per month over past year

Punithakumar, Kumaradevan, Li, Shuo, Ben Ayed, Ismail, Ross, Ian, Islam, Ali and Chong, Jaron. 2009. « Heart motion abnormality detection via an information measure and bayesian filtering ». In Medical Image Computing and Computer-Assisted Intervention – MICCAI 2009. 12th International Conference, London, UK, September 20-24, 2009, Proceedings, Part II (London, UK, Sept. 20-24, 2009) Coll. « Lecture Notes in Computer Science », vol. 5762. pp. 373-380. Springer Verlag.
Compte des citations dans Scopus : 6.

[thumbnail of Ben Ayed I 2009 10560 Heart motion abnormality detection via an information measure and bayesian filtering.pdf]
Preview
PDF
Ben Ayed I 2009 10560 Heart motion abnormality detection via an information measure and bayesian filtering.pdf

Download (223kB) | Preview

Abstract

This study investigates heart wall motion abnormality detection with an information theoretic measure of heart motion based on the Shannon’s differential entropy (SDE) and recursive Bayesian filtering. Heart wall motion is generally analyzed using functional images which are subject to noise and segmentation inaccuracies, and incorporation of prior knowledge is crucial in improving the accuracy. The Kalman filter, a well known recursive Bayesian filter, is used in this study to estimate the left ventricular (LV) cavity points given incomplete and noisy data, and given a dynamic model. However, due to similarities between the statistical information of normal and abnormal heart motions, detecting and classifying abnormality is a challenging problem which we proposed to investigate with a global measure based on the SDE. We further derive two other possible information theoretic abnormality detection criteria, one is based on R´enyi entropy and the other on Fisher information. The proposed method analyzes wall motion quantitatively by constructing distributions of the normalized radial distance estimates of the LV cavity. Using 269×20 segmented LV cavities of short-axis magnetic resonance images obtained from 30 subjects, the experimental analysis demonstrates that the proposed SDE criterion can lead to significant improvement over other features that are prevalent in the literature related to the LV cavity, namely, mean radial displacement and mean radial velocity.

Item Type: Conference proceeding
ISBN: 03029743
Editors:
Editors
ORCID
Yang, Guang-Zhong
UNSPECIFIED
Hawkes, David
UNSPECIFIED
Rueckert, Daniel
UNSPECIFIED
Noble, Alison
UNSPECIFIED
Taylor, Chris
UNSPECIFIED
Professor:
Professor
Ben Ayed, Ismail
Affiliation: Autres
Date Deposited: 11 Sep 2015 15:39
Last Modified: 01 Dec 2015 15:02
URI: https://espace2.etsmtl.ca/id/eprint/10560

Actions (login required)

View Item View Item