Hamouda, Mahmoud, Blanchette, Handy Fortin and Al-Haddad, Kamal.
2016.
« Unity power factor operation of indirect matrix converter tied to unbalanced grid ».
IEEE Transactions on Power Electronics, vol. 31, nº 2.
pp. 1095-1107.
Compte des citations dans Scopus : 59.
Preview |
PDF
Al-Haddad K. 2016 11700 Unity Power Factor Operation.pdf - Accepted Version Use licence: All rights reserved to copyright holder. Download (1MB) | Preview |
Abstract
This paper presents a new control method for indirect matrix converter operating under unbalanced grid voltages. The proposed method aims to achieve balanced output voltages as well as a near unity input power factor operation. First, an opportune reference current accurately generated, and a proportional integral resonant controller are designed in a dq reference frame that is synchronized with the positive sequence of the grid voltages so as to achieve a perfect tracking of input reactive power reference. Then, a real-time estimator of the virtual dc-link voltage is developed with the aim to provide balanced output voltages; therefore, an almost constant active power free of low frequency ripple is supplied from the grid. Experimental results are presented to verify the feasibility and effectiveness of the proposed control method.
| Item Type: | Peer reviewed article published in a journal |
|---|---|
| Professor: | Professor Al Haddad, Kamal |
| Affiliation: | Génie électrique |
| Date Deposited: | 29 Oct 2015 15:18 |
| Last Modified: | 06 Apr 2017 20:55 |
| URI: | https://espace2.etsmtl.ca/id/eprint/11700 |
Actions (login required)
![]() |
View Item |