Handrim reaction force and moment assessment using a minimal IMU configuration and non-linear modeling approach during manual wheelchair propulsion

Aissaoui, Rachid, De Lutiis, Amaury, Feghoul, Aiman et Chénier, Félix. 2024. « Handrim reaction force and moment assessment using a minimal IMU configuration and non-linear modeling approach during manual wheelchair propulsion ». Sensors, vol. 24, nº 19.

[thumbnail of Aissaoui-R-2024-29772.pdf]
Prévisualisation
PDF
Aissaoui-R-2024-29772.pdf - Version publiée
Licence d'utilisation : Creative Commons CC BY.

Télécharger (4MB) | Prévisualisation

Résumé

Manual wheelchair propulsion represents a repetitive and constraining task, which leads mainly to the development of joint injury in spinal cord-injured people. One of the main reasons is the load sustained by the shoulder joint during the propulsion cycle. Moreover, the load at the shoulder joint is highly correlated with the force and moment acting at the handrim level. The main objective of this study is related to the estimation of handrim reactions forces and moments during wheelchair propulsion using only a single inertial measurement unit per hand. Two approaches are proposed here: Firstly, a method of identification of a non-linear transfer function based on the Hammerstein–Wiener (HW) modeling approach was used. The latter represents a typical multi-input single output in a system engineering modeling approach. Secondly, a specific variant of recurrent neural network called BiLSTM is proposed to predict the time-series data of force and moments at the handrim level. Eleven subjects participated in this study in a linear propulsion protocol, while the forces and moments were measured by a dynamic platform. The two input signals were the linear acceleration as well the angular velocity of the wrist joint. The horizontal, vertical and sagittal moments were estimated by the two approaches. The mean average error (MAE) shows a value of 6.10 N and 4.30 N for the horizontal force for BiLSTM and HW, respectively. The results for the vertical direction show a MAE of 5.91 N and 7.59 N for BiLSTM and HW, respectively. Finally, the MAE for the sagittal moment varies from 0.96 Nm (BiLSTM) to 1.09 Nm for the HW model. The approaches seem similar with respect to the MAE and can be considered accurate knowing that the order of magnitude of the uncertainties of the dynamic platform was reported to be 2.2 N for the horizontal and vertical forces and 2.24 Nm for the sagittal moments. However, it should be noted that HW necessitates the knowledge of the average force and patterns of each subject, whereas the BiLSTM method do not involve the average patterns, which shows its superiority for time-series data prediction. The results provided in this study show the possibility of measuring dynamic forces acting at the handrim level during wheelchair manual propulsion in ecological environments.

Type de document: Article publié dans une revue, révisé par les pairs
Professeur:
Professeur
Aissaoui, Rachid
Affiliation: Génie des systèmes
Date de dépôt: 05 nov. 2024 19:46
Dernière modification: 07 nov. 2024 20:23