Low-cost commercial hydrogen sensor for measuring unburned hydrogen in engine exhaust

Sperling, Ed, Gordon, David et Koch, Bob. 2025. « Low-cost commercial hydrogen sensor for measuring unburned hydrogen in engine exhaust ». In Proceedings of the CSME-CFDSC-CSR 2025 International Congress (Montreal, QC, Canada, May 25-28, 2025) Coll. « Progress in Canadian Mechanical Engineering », vol. 8.

[thumbnail of 482 - Low-cost commercial hydrogen senso.pdf]
Prévisualisation
PDF
482 - Low-cost commercial hydrogen senso.pdf - Version publiée
Licence d'utilisation : Tous les droits réservés aux détenteurs du droit d'auteur.

Télécharger (218kB) | Prévisualisation

Résumé

A commercial low-cost hydrogen sensor, based on the catalytic oxidation principle, is investigated for suitability in sensing emissions of unburned hydrogen from diesel dual-fuel engines. This sensor is insensitive to oxygen level over the range of 0-3 vol% hydrogen and 8-20% oxygen, exhibiting RMS error of 0.04 H2% in this region. Linear cross-sensitivity to carbon monoxide at 0.392 H2%/CO% is observed. Cross-sensitivity to propane, carbon dioxide, and nitrogen monoxide are deemed negligible. Once the effect of carbon monoxide is taken into account, readings of real engine exhaust match gas chromatography to RMS error of 0.02 H2%, demonstrating that this sensor is suitable for measuring hydrogen in engine exhaust.

Type de document: Compte rendu de conférence
Éditeurs:
Éditeurs
ORCID
Hof, Lucas A.
NON SPÉCIFIÉ
Di Labbio, Giuseppe
NON SPÉCIFIÉ
Tahan, Antoine
NON SPÉCIFIÉ
Sanjosé, Marlène
NON SPÉCIFIÉ
Lalonde, Sébastien
NON SPÉCIFIÉ
Demarquette, Nicole R.
NON SPÉCIFIÉ
Date de dépôt: 18 déc. 2025 15:33
Dernière modification: 18 déc. 2025 15:33
URI: https://espace2.etsmtl.ca/id/eprint/32508

Actions (Authentification requise)

Dernière vérification avant le dépôt Dernière vérification avant le dépôt