Hannat, Ridha et Morency, François.
2014.
« Numerical validation of conjugate heat transfer method for anti-/de-icing piccolo system ».
Journal of Aircraft, vol. 51, nº 1.
pp. 104-116.
Compte des citations dans Scopus : 35.
Prévisualisation |
PDF
Morency F. 2014 7330 Numerical validation of conjugate heat transfer method for.pdf - Version acceptée Licence d'utilisation : Tous les droits réservés aux détenteurs du droit d'auteur. Télécharger (3MB) | Prévisualisation |
Résumé
Anti-/de-icing CHT method based on ANSYS-CFX flow solver and FENSAP-ICE software is presented. The ANSYS-CFX flow solver is used as the flow solver module with the k −ω SST turbulence model. DROP3D is used as the droplet impingement module. ICE3D is used as the ice accretion and water film runback module. CHT3D/CFX is used for the thermal coupling of all modules. Before solving for the temperature distribution in a 3D anti-icing system geometry based on a piccolo tube with three jet rows, a test case consisting of a two stream parallel gas to gas micro heat exchanger will validate the CHT3D/CFX procedure. For the anti-icing system in wet air mode temperature results at corresponding experimental locations are presented and compared to results from literature.
Type de document: | Article publié dans une revue, révisé par les pairs |
---|---|
Professeur: | Professeur Morency, François |
Affiliation: | Génie mécanique |
Date de dépôt: | 27 mars 2014 15:45 |
Dernière modification: | 04 août 2015 18:55 |
URI: | https://espace2.etsmtl.ca/id/eprint/7330 |
Actions (Authentification requise)
Dernière vérification avant le dépôt |